BSLWR - ULTRA-TECHNEKOW FM,TECHNETIUM TC99M GENERATOR

  • MSDS: BSLWR
  • Manufacturer: MALLINCKRODT INC
  • Product Name: ULTRA-TECHNEKOW FM,TECHNETIUM TC99M GENERATOR
  • National Stock Number: 6505-00F030803
Product Identification

Product ID:ULTRA-TECHNEKOW FM,TECHNETIUM TC99M GENERATOR
MSDS Date:11/18/1985
FSC:6505
NIIN:00F030803
MSDS Number: BSLWR

Responsible Party
MALLINCKRODT INC
675 MCDONNELL BLVD
ST. LOUIS, MO 63134
US

Emergency Phone: 314-895-2000/314-982-5000

Info Phone: 314-895-2000

Cage: 37940

Contractor
MALLINCKRODT INC
5840 ST. LOUIS, MO 63134 US

Telephone: 314-539-1600

Cage: 37940

Ingredients

MOLYBDIC ACID DISODIUM SALT *93-3*

CAS: 38848-45-2


SODIUM PERTECHNETATE TC 99 *93/1*

CAS: 23288-60-0

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE SYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS OR TISSUES. EYES:
MECHANICAL IRRITATION. CHRONIC: HEALTH RISK ASSOCIATED W/CHRONIC
RADIATION EXPOSURE SUCH AS CANCER, LE UKEMIA, GENETIC & TERATOGENIC
EFFECTS INVOLVES LEVELS OF EXPOSURE MUCH HIGHER THAN THOSE
PERMITTED OCCUPATIONALLY.
Explanation of Carcinogenicity:NONE

First Aid

First Aid:INGESTION: NOTIFY RADIATION SAFETY PERSONNEL IMMEDIATELY. THE
AMOUNT OF MATERIAL ASSESSED & DOCUMENTED. SKIN: WASH THOROUGHLY
W/SOAP & WATER UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. ALWAYS
BLOT DRY . DON'T ABRADE SKIN. EYES: FLUSH W/WATER FOR AT LEAST 15
MINS OR UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. OBTAIN MEDICAL
ATTENTION IN ALL CASES. (SEE SUPPLEMENTAL INFORMATION).

Fire Fighting

Extinguishing Media:MEANS SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH APPROVED
SELF-CONTAINED BREATHING APPARATUS W/FULL FACEPIECE OPERATED IN
PRESSURE-DEMAND OR OTHER POSITIVE PRESSURE MODE.

Accidental Release

Spill Release Procedures:IF PRODUCT IS RECEIVED IN DAMAGED CONDITION OR
ANY LOSS OR RELEASE OF RADIOACTIVE CONTENTS OCCURS, NOTIFY
RADIATION SAFETY DEPARTMENT & MALLINCKRODT.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. HANDLING
TIME SHOULD BE KEPT TO A MINIMUM/SHIELDING SHOULD BE USED.
RADIOACTIVE DRUGS MUST BEHANDLED BY QUALIFIED PERSONNEL
Other Precautions:HANDLING DEVICES SUCH AS SYRINGE SHIELDS & TONGS
SHOULD BE USED. NO SMOKING, EATING OR DRINKING SHOULD BE ALLOWED IN
ANY AREA WHERE RADIOACTIVE MATERIALS ARE HANDLED OR STORED.

Exposure Controls

Protective Gloves:DISPOSABLE PLASTIC, LATEX OR RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING.
Supplemental Safety and Health
TOXICITY DATA: SUFFICIENT QUANTITIES OF IONIZING RADIATION CAN
POTENTIALLY CAUSE HARMFUL BIOLOGICAL EFFECTS. CURIE QUANTITIES
INJECTED INTO BODY MAY CAUSE ACUTE RADIATION SICKNESS.
CONCENTRATION: 25-3 00 MCI/ML ON CALIBRATION WHEN ELUTED W/10 ML
EVACUATED VIALS. SPECIFIC ACITIVITY: 480 MCI/MICROGRAMS OF
MOLYBDENUM.

Chemical Properties

Boiling Pt:B.P. Text:212F ELUATE
Melt/Freeze Pt:M.P/F.P Text:32F ELUATE
Solubility in Water:COMPLETE
Appearance and Odor:ELUATE- CLEAR, COLORLESS, STERILE, PYROGEN-FREE,
ISOTONIC SOLUTION, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:RADIOACTIVE FUMES CONTAINING
RADIOACTIVE MOLYBDENUM & TECHNETIUM

Disposal

Waste Disposal Methods:DISPOSE OF IN CONTROLLED MANNER IN ACCORDANCE
W/FEDERAL, STATE & LOCAL REGULATIONS. DOT: RADIOACTIVE MATERIAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.